set ProIO Servo RS485 Output to Dynamixel Servo‐unit from Robotis. set RS232‐2 to Dynamixel Servo‐unit from Robotis. WEIGL ASCII‐Commands for ProCommander Series, WEMC‐1 and Pro I/O Series Command new DMX‐Merge End channel is stored in EE‐Prom. New DMX‐Merge Start channel is stored in EE‐Prom. 5: Between Start‐ and End‐Channel the output follows the external DMX‐Signal. 4: The values of both DMX signals are added maximum value = 255. 3: Output is that value, which has changed at last. 2: Output is the highest value of both DMX signals. 1: Output is the lowest value of both DMX signals. ProLX: set treble value 5 on audio channel 3. New Master Treble value is stored in EE‐Prom. ProLX: all channels are set to treble 10. ProLX: set bass value 5 on audio channel 3. New Master Bass value is stored in EE‐Prom. ProLX: all channels are set to bass value 10. ProLX: set volume level 10 on audio channel 2. ![]() new Master Volume level is stored in EE‐Prom. ProLX: all channels are set to volume 25. ![]() new Gateway IP Adress is stored in EE‐Prom. reboots the unit in the same way as a power cycle would do. The programmer has to take care about the correct syntax! Wrong commands are ignored or lead to a unexpected result! Set port1 ‐‐ port4 Set Gateway IP‐address Set sub‐net mask Set master volume set DMX‐merge mode DMX‐Merge Mode 0: Merge‐None 1: Merge‐LTP 2: Merge‐HTP 3: Merge‐Change 4: Merge‐Add 5: Merge‐Combine If Merge‐Mode is enabled, it is only valied between start‐ and end‐channel. Set master treble Master Treble ] Channel number for ProCommander LX only. Set master bass Master Bass ] Channel number for ProCommander LX only. Port IP‐Address Sub‐Net Mask Master Volume Channel number for ProCommander LX only. IP‐Address MAC‐address, IP‐Address, sub‐net mask ![]() Set factory Reboot unit Set IP‐address Set IP‐address and sub‐net mask Commands marked in this colour are not implemented yet! Commands marked in this colour are only possible in the Control.ini file!Īll changes with the set commands are stored in the internal EE‐Prom Port: RS232‐1 If these serial parameters are changed, the transmitter must be changed to the same parameters! Maximum length of a serial string for port RS232‐1: 150 characters. WEIGL ASCII‐Commands for ProCommander Series, WEMC‐1 & ProIO Series Default connection parameter: 9600 baud, 8 data bits, no parity, 1 stop bit. WEIGL ASCII‐Commands for ProCommander Series, WEMC‐1 and Pro I/O Series
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |